Is one air conditioner enough for 10 mining machines
Publish: 2021-04-14 11:55:52
1. It's OK. Anyway, there's no such excuse as "power cut door", "air conditioning door" and "maintenance door". It's almost half a year now. I stopped the electricity once. I don't know how much electricity you take now. Anyway, the electricity was a little expensive at that time. Ask the customer service here. Anyway, what's the cost of speculation
2. The safe current carrying capacity of 10 square aluminum wires is about 50a, and the current of a 1p air conditioner is about 4a. Considering that a certain margin is 5a, it can only be basically enough.
3. Family three air conditioning is generally a cabinet and two wall mounted. The operation power of
cabinet machine is about 5500w, and the maximum power of two wall mounted machines is about 3500W
the total power is 9000W and the current is 40A. No other load, use 6 square copper wire.
cabinet machine is about 5500w, and the maximum power of two wall mounted machines is about 3500W
the total power is 9000W and the current is 40A. No other load, use 6 square copper wire.
4. Do you need me to teach you this? Look at the total power and current of ten air conditioners.
5. 10 square meters of open wire laying, the safety cut-off flow is about 74a
the rated power of 10 1.5p air conditioners is about 11000w and the current is about 55A
for safety, a 16 square line is recommended.
the rated power of 10 1.5p air conditioners is about 11000w and the current is about 55A
for safety, a 16 square line is recommended.
6. Yes, the room is not very big. One air conditioner is enough, and it's a straight line. It's completely OK. The split type is OK. My house is factory shaped, a little bigger than your house. One of them is very cool. It's better to open two rooms instead of the kitchen. The key is the refrigeration effect of the air conditioner
7. The Kelon air conditioner that our family bought in the summer of 1997 has just been repaired (it may be that we forgot to pull out the plug last year and burned an original one). Now it can still be used, but the maintenance personnel said that it may need to add fluorine every year, and the refrigeration effect is not as good as before.
8. Generally:
2200 ~ 2600w -------- 1
3200 ~ 3600W -------- 1.5
not enough
and even if enough
the air conditioner is always running to maintain the room temperature
the machine is damaged greatly
just like a small horse pulling a cart
the horse runs slowly
the horse dies fast
2200 ~ 2600w -------- 1
3200 ~ 3600W -------- 1.5
not enough
and even if enough
the air conditioner is always running to maintain the room temperature
the machine is damaged greatly
just like a small horse pulling a cart
the horse runs slowly
the horse dies fast
9. 1. The entrance line is 3x10mm and 178+ 2X6mm² The copper core cable is grounded by three fire one zero one. The three-phase power supply should be equally distributed as far as possible
2. Single phase can be selected for three floors, and three-phase can be used for one floor
3. Dz47-63 series miniature circuit breaker d102p (each lamp is 100W) is used for lighting, and leakage protection C16 and C20 are used for socket
4. The single-phase incoming copper wire should be 2x95mm+ 1X6mm² Yes, it's too inconvenient and uneconomic for construction. It's not recommended
5. If it is possible (considering the possibility of adding other electrical appliances) to upgrade the incoming cable to a higher level, choose 3x16mm + 2x10mm & # 178; Copper core power cable.
2. Single phase can be selected for three floors, and three-phase can be used for one floor
3. Dz47-63 series miniature circuit breaker d102p (each lamp is 100W) is used for lighting, and leakage protection C16 and C20 are used for socket
4. The single-phase incoming copper wire should be 2x95mm+ 1X6mm² Yes, it's too inconvenient and uneconomic for construction. It's not recommended
5. If it is possible (considering the possibility of adding other electrical appliances) to upgrade the incoming cable to a higher level, choose 3x16mm + 2x10mm & # 178; Copper core power cable.