Monero mining software is not responding
Cause analysis:
most of the information on the Internet is e to the following three reasons:
one of the reasons for this problem: the guiminer program is incomplete, please download the green pure version again
the second reason for this problem is that your computer's Windows Installer service is not turned on
the solution is to open the control panel → management → service, start the Windows Installer service, set it to automatic, and then restart the computer
the third reason for this problem is that you do not have the runtime of visual studio installed on your computer
this application is developed by Visual Studio 2005 and above, and it depends on the corresponding runtime, which is not installed on your computer For the application developed by VC6 or VS2003, if the library file is missing, it will prompt that "* *. DLL" is missing. However, for the application developed by VS2005 or VS2008, it will only prompt that "e to the incorrect configuration of the application...")
the solution is not to reload the application program or the system, but to install the corresponding runtime (Microsoft Visual C + + 20 * * redistributable package, vcredist)_ x86.exe
} it's really difficult to distinguish which version of vs your program is developed, and even some software is developed in multiple versions, that is, multiple vcredist_ X86.exe are installed, they are compatible with each other, you can solve most of your computer software problems of the same kind After 2005 and 2008 are installed, "add / Remove Programs" will be displayed, as shown in Figure 5)
- "20 * *" stands for "2005" or "2008" or "2009" or "2010" below
required installation package
only need one file_ X86.exe
steps
open the control panel → management tools → services. If the Windows Installer service is not started, set it to automatic, and then restart the computer. If the problem is not solved, continue
you can preliminarily judge which version of vs your program was developed
(open the directory where the application is located, and search whether there are files beginning with MFC or MSVC. If there are, please check the file version to know the VC version. As shown in the figure below, 8 is developed by VC8.0, 9 is developed by vc9.0)
the VC version of VS2003 is VC. 1,
the VC version of VS2005 is VC8.0,
the VC version of VS2008 is vc9.0
check whether Microsoft Visual C + + 20 * * redistributable package is installed in the "add / Remove Programs" of the control panel
if there is no Microsoft Visual C + + 20 * * redistributable in the figure above, continue
download the Microsoft Visual C + + 20 * * redistributable package from the Microsoft Download Center. The file has 32 bits (x86) and 64 bits (x64). The download address is as follows
double click to run the vcredist downloaded just now_ X86.exe, which will automatically install Microsoft Visual C + + 20 * * redistributable package
check whether there is this item in "add / Remove Programs"
if there is this item, it means the installation is successful. Then open your application, if there is no error, then the problem is solved
view the original post & gt& gt;
bit B is not so easy to dig.
people may not be able to dig out a supercomputer with thousands of dollars in a year.
you can dig out a cell phone... Then bit B is not so valuable···
secondly, mining requires the computer to be running all the time and can't be turned off, which requires a lot of computer. It is harmful for each part to do a lot of calculation for a long time, and it also requires high power supply for the computer
mining can't be powered off, and it needs to be recalculated after power off. Graphics card long time to do a lot of calculations will lead to greatly shorten the life of the graphics card, so their own home, do not recommend mining, mining is not as expensive as electricity.
method 2. When you start the system, click the F8 key to enter the system operation menu (if it is win8, win8.1, win10 system, after seeing the boot screen, press the power button for a long time to shut down, and repeat about three times in a short time to enter winre {windows recovery environment}, but some users may need to disconnect the power directly. In this way, the advanced recovery interface should appear after boot), and then look for "safe mode", and enter "safe mode". If you can successfully enter, click "start" → "all programs" → "accessories" → "system tools" → "system restore", and "system restore dialog box" will appear, and select "restore my computer to an earlier time". In this way, you can use the system restore function of windows system to restore to a restore point when you can boot normally before If any)
method 3. Try electrostatic discharge treatment. Remove the power cord and battery of your computer after power off; Long press the power on button (more than 30 seconds), and then try to restart
method 4. Use the system installation CD-ROM or system installation U-disk, insert the CD-ROM drive or USB interface, restart the computer, enter the CD-ROM installation system state or enter the U-disk installation system state, wait until the startup interface flashes, do not choose to install the system, but choose to repair the system, and repair the current system (it may run for a long time, 2-4 hours), Wait patiently for the repair to complete to see if it can solve the problem At the end of this paper, the method of setting USB flash disk as the first boot device is described in detail.
if the above four methods are invalid, you can only reload the system.